Block 5 — Observe the Updated Data Flow¶
Duration: 45 min
Steps¶
- Return to the IoT Core → Test → MQTT test client and observe: metric values now have 3 decimal places (
"cpu_pct": 12.450instead of12). -
Return to Athena workgroup
workshop-sharedand run this query to confirm the precision change is visible in the archive:SELECT thing_name, max_by(cpu_pct, ingest_ts) AS latest_cpu_pct, max_by(mem_used_pct, ingest_ts) AS latest_mem_used_pct, max_by(disk_used_pct, ingest_ts) AS latest_disk_used_pct, from_unixtime(MAX(ingest_ts) / 1000) AS latest_edge_ts, current_timestamp AS query_ts, date_diff('second', from_unixtime(MAX(ingest_ts) / 1000), current_timestamp) AS freshness_seconds, COUNT(*) AS row_count FROM workshop_telemetry.telemetry WHERE deployment_id = 'ws-slot00' GROUP BY thing_name ORDER BY freshness_seconds DESC;The
latest_*columns pull each metric from the most-recent row per device, so the 3-decimal precision (e.g.12.45) is visible directly in the result.AWS CLI equivalent
QUERY_ID=$(aws athena start-query-execution \ --work-group workshop-shared \ --query-string "SELECT thing_name, max_by(cpu_pct, ingest_ts) AS latest_cpu_pct, max_by(mem_used_pct, ingest_ts) AS latest_mem_used_pct, max_by(disk_used_pct, ingest_ts) AS latest_disk_used_pct, from_unixtime(MAX(ingest_ts)/1000) AS latest_edge_ts, current_timestamp AS query_ts, date_diff('second', from_unixtime(MAX(ingest_ts)/1000), current_timestamp) AS freshness_seconds, COUNT(*) AS row_count FROM workshop_telemetry.telemetry WHERE deployment_id='ws-slot00' GROUP BY thing_name ORDER BY freshness_seconds DESC" \ --query QueryExecutionId --output text) for _i in $(seq 1 20); do STATE=$(aws athena get-query-execution \ --query-execution-id "$QUERY_ID" \ --query 'QueryExecution.Status.State' --output text) if [ "$STATE" = "SUCCEEDED" ] || [ "$STATE" = "FAILED" ] || [ "$STATE" = "CANCELLED" ]; then break fi sleep 3 done echo "$STATE" aws athena get-query-results \ --query-execution-id "$QUERY_ID" \ --query 'ResultSet.Rows[*].Data[*].VarCharValue' --output table -
Observe that rows added after the job succeeded have decimal-precision values (e.g.
12.45) — the Iceberg table declarescpu_pct,mem_used_pct, anddisk_used_pctasdoublecolumns, so the full precision published over MQTT is preserved all the way into Athena.
Discussion¶
- The fleet update happened without SSH, without manual intervention, with per-device status tracking — what does this mean for a fleet of 300 remote sites?
- The freshness is the same as Session 1 — why doesn't the precision change affect Athena latency at all?
- What would you need to change in the pipeline to reduce archive-tier latency for compliance/audit use cases?
Wrap-Up¶
Recap the IoT Jobs model: job document → rollout config → per-device status lifecycle.
Preview Session 3: Next week you'll add device shadows for health and deployment state, then use the front-end UI to observe device state and experience failure detection via shadow staleness.